The arcoPlus®Onda Curvo system allows for the creation of continuous translucent roofing or can be used, by means of lateral overlapping, with curved fibre cement sheets or insulating panels with a bending radius of R.3,500mm.
The arcoPlus®Onda profile must be installed with the UV protected side facing outwards, in order to keep the optical and mechanical properties of the material unchanged over time.

6mm
arcoPlus® Onda

Applications of Overlapping Sistems arcoPlus® Onda

Production standards

Sound insulation Rw (ISO 717-1) 16dB
Available colors Cristallo/Opale
Panel length 5,000mm (max recommended)
Thickness 6mm
Wave height 51mm
Wave passage 177mm
Usable module width 1.050mm (875 su richiesta)
Thermal transmittance U 3,2 W/m2K

Features

Linear thermal expansion 0,065mm/m°C
Operating temperature -40°C +120 °C
UV protection Co-extrusion
Reaction to fire EN 13501-1 EuroClass B-s1,d0
MIN slope (lucernario) 5%
MIN slope (copertura continua) 7%
Minimum bending radius 3,5m
Light transmission (τv) Clear 73%

Strengths

Ease and cost-effective installation
Thermal insulation
Light transmission
High load resistance
Resistance to UV radiation and hail
Longitudinal overlap
Lateral overlap

Special treatments

435-logo_IR.png444-logo_UVT.png

Flow rate tables

The system's flow rate values differ depending on the type of application. Click on the following icons to see the centre-to-centre distances required based on the permissible load.

Permissible loads fot flat installation on multiple supports (arcoPlus ONDA) - roof
Permissible loads for curved installation on 2 supports (arcoPlus ONDA) - roof
Permissible loads fot flat installation on multiple supports (arcoPlus ONDA) - skylight
Permissible loads for curved installation on 2 supports (arcoPlus ONDA) - skylight
× Download
Move the cursors to set sheet measures
Dependent value: m
Dependent value: m

Skylight ridge-to-eaves piano - arcoPlus®Onda

Skylight ridge-to-eaves piano - arcoPlus®Onda

Panels laterally overlapped with corrugated insulated roofing panels or fiber-cement sheets. Minimum recommended slope 7%.

roof foot at the eaves line with PE gasket.
Detail of overlap between panels in ridge-to-eaves application using a PE gasket.
detail of the internal multiwall structure of arcoPlusONDA

Continuous roofing flat - arcoPlus®Onda

Continuous roofing flat - arcoPlus®Onda

Construction of continuous roofing/wall, obtained by continuous lateral overlap of polycarbonate panels.

Walls and vertical partitions

Walls and vertical partitions

Translucent vertical partitions can also be created simply by laterally overlapping the panels. This application is used in the context of trade-show fittings, industrial environments, warehouses and office partitions.

Vertical dividing wall in arcoPlus ONDA

Skylight curvo

Skylight curvo

Construction of skylights obtained by lateral overlap of translucent elements alternating with opaque fiber-cement sheets.

Development table R.3,500 m

Chord Rise Development
1,000 36 1,015
1,200 52 1,220
1,400 71 1,420
1,600 93 1,630
1,800 118 1,835
2,000 146 2,045
2,200 177 2,255
2,400 212 2,470
2,600 250 2,685
2,800 292 2,905
3,000 338 3,125

Maximum development

Radius 3,500 mm
Development 5,300
Continuous roofing curved - arcoPlus®Onda

Continuous roofing curved - arcoPlus®Onda

Construction of continuous roofing, obtained by continuous lateral overlap of polycarbonate elements. Bending radius R.3,500 mm.


continuous curved roofing in arcoPlusONDA in an inner courtyard for parking protection
continuous curved roofing for a pedestrian entrance to a residential building