The arcoPlus® miniGreca5 system allows for the creation of continuous translucent roofs and skylights with eaves combined with grey panels for roofs. Taking into account the linear thermal expansion of polycarbonate and to avoid any cracks at the through fastening elements, a maximum usable length of 5,000 mm is recommended; for greater pitch lengths, the special design of the profile makes the panels perfectly overlappable, allowing for the creation of overlaps at the underlying supports.
| Structure | 3 walls |
|---|---|
| Available colors | Cristallo/Opale |
| Thickness | 8mm |
| Greek height | 40mm |
| useful module width | 995 ± 10mm |
| Maximum recommended length | 5000 mm |
| Linear thermal expansion | 0,065mm/m°C |
|---|---|
| Operating temperature | -40°C +120 °C |
| UV protection | Co-extrusion |
| Reaction to fire EN 13501-1 | EuroClass B-s1,d0 |
| Thermal insulation | 3,0 W/m²K |
| Acoustic insulation | 16 dB |
| Thermal insulation | |
| Light transmission | |
| Resistance to UV radiation and hail | |
| Longitudinal overlap | |
| Thermally welded panels | |
| Transversal overlap |
The system's flow rate values differ depending on the type of application. Click on the following icons to see the centre-to-centre distances required based on the permissible load.
The panels are supplied as standard with heat-sealed ends to prevent dirt from entering the internal cells. For correct installation, it is recommended to pre-drill the panels with a slot having a diameter at least 3 mm larger than the screw diameter in order to compensate for the material’s thermal expansion.
RIDGE-TO-EAVES SKYLIGHTS: Flat translucent skylights are obtained by installing arcoPlus®MiniGreca5 through lateral overlap with insulated roofing panels, using appropriate cap screws for fastening. A minimum roof slope of 5% is recommended. IN-PLANE RIDGE SKYLIGHTS: In-plane skylights made with arcoPlus®MiniGreca5 are positioned at the upper part of the slope, anchoring to the roof ridge, and are matched with Isolpack®Delta5 and Alubel®Dach insulated panels. A minimum roof slope of 5% is recommended.
![]() |
| continuous translucent roofing to protect terraces and verandas |
![]() |
| detail of the eaves end of the skylights with insertion of PE bird-stop |
![]() |
| possibility to choose between 2 different heights of the lateral overlap flanges |
![]() |
| detail of anchoring at the roof foot with curved application |
Construction of continuous roofing by continuous lateral overlap of the panels. Minimum recommended slope 7%.